| Código HS | 163383 |
| Nombre Químico | alcohol polivinílico |
| Fórmula Química | (C2H4O) |
| Solubilidad En Agua | Soluble en agua |
| Biodegradabilidad | Biodegradable en condiciones aeróbicas y anaeróbicas |
| Capacidad De Formación De Películas | Excelente propiedad formadora de películas |
| Flexibilidad | Propiedades mecánicas ajustables de alta flexibilidad con |
| Resistencia A La Tracción | 10-100 MPa dependiendo del peso molecular y el procesamiento |
| Elongación En La Ruptura | 10-400% dependiendo del contenido de plastificante y la humedad |
| Temperatura De Transición Vítrea | 60-85 ° C |
| Punto De Fusión | 180-230 °C |
| Transparencia Óptica | Transparente en rango visible |
| Biocompatibilidad | No tóxico y biocompatible |
| Constante Dieléctrica | 3-6 a 1 kHz |
| Conductividad Iónica | Dopantes mejorables con para aplicaciones de detección |
| Hidrofilicidad | Grupos hidroxilo con altamente hidrofílicos |
Como fábrica acreditada de Alcohol polivinílico (PVA) para materiales de sensores flexibles, hacemos cumplir estrictos protocolos de calidad: cada lote se somete a rigurosas pruebas para garantizar estándares consistentes de eficacia y seguridad.
| Embalaje | Empaquetado en tambores sellados herméticos y resistentes a la humedad, 5 kg por contenedor, lo que garantiza la pureza y la estabilidad para aplicaciones de materiales de sensores flexibles. |
| Carga De Contenedores (20 'FCL) | Alcohol polivinílico para materiales de sensores flexibles enviados en un contenedor de 20 'FCL, paletizado, empaquetado a prueba de humedad, transporte seguro y protegido. |
| Envío | Alcohol de polivinilo (PVA) para materiales de sensores flexibles se envía como un polvo seco no peligroso en bolsas o tambores sellados y resistentes a la humedad. Almacene lejos de la humedad y el calor extremo. Utilice transporte de carga seca estándar a temperatura ambiente, evitando la luz solar directa. El etiquetado adecuado y el manejo seguro garantizan una entrega estable y sin daños. |
| Almacenamiento | Almacene el alcohol polivinílico (PVA) en un recipiente hermético herméticamente cerrado en un ambiente fresco y seco por debajo de 25 ° C. Proteger de la humedad, la luz solar directa y la humedad, ya que el PVA es higroscópico y soluble en agua. Mantener alejado de agentes oxidantes y fuentes de ignición. El almacenamiento adecuado evita el apelmazamiento, la degradación y mantiene la pureza para aplicaciones de sensores flexibles. |
| Duración | Vida útil: normalmente de 2 a 3 años cuando se almacena sellado, seco y lejos de la humedad, manteniendo una flexibilidad y un rendimiento óptimos del sensor. |
Aqueous solutions of partially hydrolyzed PVA grade PVA 1788 (degree of hydrolysis 87–89%, 4% aqueous viscosity 21–33 mPa·s at 20 °C) are prepared at 12–15 wt% solids in deionized water under stirred heating at 90 °C for 2 h. Pre-drying of the granules at 80 °C under -0.09 MPa vacuum for 4 h is mandatory when ambient RH exceeds 60%, otherwise batch-to-batch viscosity drift exceeds ±8%. Conductive nanofiller, typically carboxylic acid-functionalized multi-walled carbon nanotubes (MWCNT-COOH) or silver nanowires (AgNW) with aspect ratio>1000, is dispersed in a separate aqueous suspension using probe ultrasonication at 20 kHz, 150 W for 15 min with temperature kept below 10 °C to prevent PVA chain scission during later blending. The filler-to-PVA mass ratio is maintained at 1:100 to 3:100 to establish a percolation network that remains below the resistive saturation plateau, yielding an initial gauge factor (GF) in the range 1.8–3.2 at 50% tensile strain. The two liquids are mixed under planetary centrifugal mixing at 2000 rpm for 3 min and degassed to 100 Pa before casting.
Film formation employs doctor blade coating onto a fluorinated ethylene propylene (FEP) carrier foil with a wet gap of 500 μm, followed by ambient drying for 24 h and subsequent thermal annealing at 60 °C for 6 h. Crosslinking is achieved through repeated freeze-thaw cycling: 3–5 cycles of freezing at -20 °C for 12 h and thawing at 25 °C for 4 h. This process induces crystalline junction zones via hydrogen bonding, eliminating the need for chemical crosslinkers that could poison the conductive filler surface. The resulting hydrogel exhibits anisotropic conductivity with a through-plane resistivity of 10²–10³ Ω·cm (ASTM D4496-21) and an in-plane resistivity an order of magnitude lower due to shear-induced filler alignment. The tensile storage modulus E' measured by dynamic mechanical analysis (ASTM D4065-20) at 1 Hz and 2% strain amplitude plateaus at 45–65 kPa after the third cycle. End products are epidermal strain sensors attached directly to human skin with medical-grade polyurethane film dressings; they require compliance with ISO 10993-5 (MEM elution cytotoxicity) and ISO 10993-10 (skin irritation, 24 h patch test) when intended for single-patient use beyond 24 h wear duration. Signal hysteresis becomes problematic below 5% strain, limiting the low-end linearity range of these PVA-MWCNT composites unless a dynamic pre-conditioning protocol of 20 strain cycles to 80% of maximum strain is implemented before calibration.
Capacitive pressure sensor stacks for robotic tactile skins integrate a PVA dielectric layer with a relative permittivity εr of 7–10 at 1 kHz when equilibrated at 40–50% RH. The grade employed is fully hydrolyzed PVA 1799 (degree of hydrolysis ≥99%, viscosity of 4% aqueous solution 50–70 mPa·s) because the minimal residual acetate groups reduce dipole relaxation losses and improve electrical breakdown strength to >150 V/μm (ASTM D149-20, DC, 0.5 mm specimen). A plasticizer, glycerol at 15–25 wt% relative to PVA, is co-dissolved to suppress crystallization during film drying and maintain a steady dielectric response across the assembly’s operating temperature range of 0–45 °C. Without plasticizer, the dielectric constant can shift by +15% when the film absorbs moisture from ambient air, introducing cross-sensitivity that degrades sensor accuracy. The PVA/glycerol blend is spin-coated onto an indium tin oxide (ITO)-coated polyethylene terephthalate (PET) electrode substrate at 2000 rpm for 40 s, producing a defect-free layer of 2.5 ± 0.2 μm dry thickness verified by spectral reflectance interferometry. Annealing at 120 °C for 10 min in a nitrogen-purged convection oven volatilizes residual water without causing thermal degradation that would onset above 200 °C.
The stack is completed by laminating a top electrode pattern formed via photolithography on a second PET film, with alignment tolerances of ±50 μm maintained across a 300 mm web width on a roll-to-roll lamination line equipped with CCD pattern registration. Capacitance change under load follows the parallel-plate relation C = ε₀ εr A/d; at a sensing element diameter of 5 mm and a baseline capacitance of 1.2 pF, the sensor resolves 10 Pa pressure increments with a signal-to-noise ratio above 20 dB after 1 kHz lock-in amplification. This assembly must comply with RoHS Directive 2011/65/EU (no lead-based soldering applied to the flex connector terminals) and with the ESD immunity requirements of IEC 61000-4-2 Level 4 (±8 kV contact discharge) when the sensor array is integrated into handheld robotic teaching pendants. A critical failure mode observed in production is delamination at the PVA/ITO interface after 100,000 flex cycles at a bend radius of 10 mm (MIT fold endurance tester, ASTM D2176-16 modified for thin films), traced to residual stress gradients when the drying profile includes a temperature ramp rate faster than 5 °C/min. Reducing the ramp rate to 2 °C/min and introducing an adhesion-promoting interlayer of 0.1 wt% polyvinylpyrrolidone (PVP K30) extends cycle life beyond 500,000 cycles, a threshold verified by continuous impedance monitoring at 10 kHz.
Flexible electrochemical amperometric oxygen sensors printed on paper substrates require a solid-state electrolyte that remains dimensionally stable at 85% RH without deliquescing. A PVA/borate gel electrolyte is compounded from PVA 1788 at 10 wt%, sodium tetraborate decahydrate (borax) at 2.5 wt% as ionic crosslinker, and potassium chloride at 0.1 M as supporting electrolyte. The borax-to-PVA hydroxyl molar ratio is held at 1:40, producing a crosslink density low enough to permit segmental chain motion for ion transport while preventing dissolution of the gel in the water absorbed during high-humidity operation. The ionic conductivity measured by electrochemical impedance spectroscopy (EIS) at 25 °C and 60% RH reaches 0.85 mS/cm in the absence of CO₂ interference. The gel precursor is screen-printed through a polyester mesh with 120 threads/cm onto a carbon working electrode pre-deposited on chromatographic paper, followed by thermal gelation at 60 °C for 30 min in a convection oven. The resulting gel thickness of 30–50 μm is controlled by mesh count and squeegee angle of 60°.
The sensor’s end use is disposable oxygen indicators for modified-atmosphere food packaging; therefore the electrolyte formulation must comply with EU Framework Regulation 1935/2004/EC on materials intended to come into contact with food, and with the specific migration limits of FCM regulation 10/2011/EU for boron (specific migration limit of 0.006 mg/kg food simulant). The PVA/borate gel has been validated to remain below this limit when separated from the food contact surface by a 23 μm PET barrier film, confirmed by total immersion test in 3% acetic acid simulant at 40 °C for 10 days. Process harmonization is challenged by pot life: the mixed screen-printing paste undergoes progressive di-diol crosslinking at ambient temperature, with viscosity doubling within 45 min. Continuous slow-speed planetary mixing at 5 rpm extends useful pot life to 2 h and eliminates the need to pre-chill the paste to 5 °C, a step that would later cause condensation-induced pinholing during gelation. A post-print conditioning step of 24 h at 50% RH and 23 °C stabilizes the ionic conductivity drift to below 2% per week, a specification confirmed by accelerated aging at 40 °C and 75% RH (ASTM F1980-21).
At relative humidity exceeding 60%, the electrical resistance of a PVA/nanocellulose composite film drops exponentially due to the swelling-driven increase in protonic conduction, forming the transduction basis for resistive humidity sensors used in building energy management systems (BEMS). PVA with a molecular weight of 31,000–50,000 g/mol and 98–99% hydrolysis (PVA 1799) is co-solubilized with 2,2,6,6-tetramethylpiperidine-1-oxyl (TEMPO)-oxidized cellulose nanofibrils (CNF, charge density 1.0–1.5 mmol/g) at a CNF:PVA dry mass ratio of 1:4. The CNF imparts dimensional stability in the swollen state: a pure PVA film expands by>30% in thickness at 95% RH, causing electrode delamination, whereas the CNF/PVA composite restricts linear expansion to <8%. The blend solution is cast onto interdigitated gold electrodes on an alumina substrate using dip coating at a withdrawal speed of 100 mm/min, yielding a sensing layer of 5 μm. After drying at 120 °C for 30 min, the sensor exhibits a resistance change from 10⁷ Ω at 20% RH to 10³ Ω at 90% RH, with hysteresis bounded to <3% RH during a full sorption–desorption cycle when conditioned with an initial thermal reset at 150 °C for 5 min to erase fabrication-related moisture history. The calibration curve is validated against a chilled-mirror dew-point hygrometer with uncertainty ±0.2 °C dew point per ISO 4677-2:2023. Conformity with the EMC directive 2014/30/EU is demonstrated by passing radiated immunity test at 3 V/m (80 MHz–1 GHz) per IEC 61000-4-3 when the sensor’s output op-amp circuit is enclosed in a contiguous copper EMI shield. A production bottleneck occurs during the dip-coating step: the rapid gelation of CNF at the solution–air interface can create streaks if the ambient relative humidity exceeds 55%, forcing a local enclosure with desiccant-dried air supply to maintain 40% RH. This coating window is specific to CNF/PVA systems and does not appear in PVA-only sensor films, which tolerate up to 65% RH.
Biodegradable strain and temperature sensors for environmental field monitoring use a PVA substrate that dissolves on-demand after data transmission, removing the need for device retrieval. PVA PVA 0588 (degree of hydrolysis 88%, viscosity 5–6 mPa·s) is preferred because its low molecular weight accelerates the dissolution rate while still permitting film formation via melt extrusion. The PVA compound is dry-blended with 30 wt% glycerol and 1 wt% calcium stearate as processing aid, then fed into a co-rotating twin-screw extruder with L/D 40:1 and barrel temperature profile from 120 °C to 180 °C at screw speed 150 rpm. The extruded cast film of 80 μm thickness is quenched on a chill roll at 10 °C to prevent crystallization that would retard dissolution. A patterned circuit of zinc traces is transfer-printed onto the PVA film; the zinc serves as both electrode and antenna element. Dissolution time in deionized water at 20 °C is 18 min for complete substrate disappearance, measured by total organic carbon (TOC) monitoring per ASTM D5904-02. This transient device falls under the scope of the EU Single-Use Plastics Directive (EU) 2019/904 only if it is considered a product, and compliance is demonstrated by showing that the dissolved PVA achieves>60% biodegradation (CO₂ evolution) in 28 days according to OECD 301B modified Sturm test. A major process incompatibility arises when photolithographic developers containing tetramethylammonium hydroxide (TMAH) contact the PVA surface: the alkaline pH>12 triggers rapid solubilization and loss of patterning fidelity within 30 s. Patterning therefore relies exclusively on shadow-mask deposition and laser ablation, both of which avoid wet chemical etchants.
Silver flake-filled PVA-based inks serve as stretchable interconnects for textile-integrated EMG sensors, replacing thermoplastic polyurethane (TPU) binders where subsequent wash-fastness requirements demand temporary print removability with hot water. The binder phase is a 15 wt% aqueous PVA solution grade PVA 2488 (degree of hydrolysis 88%, viscosity 44–50 mPa·s). Silver flakes with D50 particle size 6 μm and tap density 4.5 g/cm³ are dispersed into the binder at a volume fraction of 42 vol% using a triple-roll mill with gap settings of 15 μm (first pass) and 5 μm (second pass) to break down agglomerates. The resulting ink has a viscosity of 12–18 Pa·s at shear rate 100 s⁻¹, suitable for printing through a 77 threads/cm stainless steel mesh onto a PET release liner. Thermal curing at 100 °C for 15 min evaporates water and lightly sinters the silver flakes, yielding a sheet resistance of 35–50 mΩ/□ at 25 μm dry print thickness (measured by four-point probe per ASTM F390-21). After stretch transfer to a pre-strained elastomeric fabric, the interconnect maintains conductivity to 40% uniaxial strain before resistance increases by 10×, as measured by a tensile stage with in-situ resistance logging at 1 kHz. Compliance with OEKO-TEX Standard 100 Annex 4 for product class I requires that the cured ink’s residual formaldehyde from PVA manufacturing be below the 16 mg/kg detection limit, a threshold routinely achieved by using low-formaldehyde-emission PVA grades specified with <5 ppm formaldehyde content. Production control involves monitoring the ink’s Open Time: at 65% RH, the ink dries on the screen to produce a blocking crust within 4 min if not periodically flooded, so the press is configured with a reciprocating flood bar and a controlled hood airflow rate of 0.2 m/s to keep the open mesh count constant over 8-h shifts.
| Application | Standard | Test Method/Clause | Compliance Indicator |
|---|---|---|---|
| Epidermal strain sensor | ISO 10993-5 | MEM elution, L929 cells | Cytotoxicity grade 0–1 |
| Epidermal strain sensor | ISO 10993-10 | 24 h patch test, rabbit skin | Primary irritation index <0.4 |
| Capacitive sensor dielectric | IEC 61000-4-2 | ESD, Level 4 contact discharge | ±8 kV no permanent degradation |
| Electrochemical O₂ sensor electrolyte | Regulation (EU) 10/2011 | Migration test, 3% acetic acid, 40°C, 10 d | Boron <0.006 mg/kg |
| Resistive humidity sensor | ISO 4677-2 | Dew-point comparison, 20–90% RH | Accuracy ±2% RH after calibration |
| Transient sensor substrate | OECD 301B | CO₂ evolution, 28 d | Biodegradation>60% |
| Printed interconnect ink | ASTM F390-21 | Four-point probe | Rs 35–50 mΩ/□ |
| Printed interconnect ink | OEKO-TEX Standard 100 | Annex 4, formaldehyde extraction | <16 mg/kg |
Alcohol polivinílico competitivo (PVA) para materiales de sensores flexibles precios que se ajustan a su presupuesto - términos flexibles y citas personalizadas para cada pedido.
Para muestras, precios o más información, contáctenos en +8615380400285 O envíelo por correo a sales2@liwei-chem.com.
Le responderemos lo antes posible.
Teléfono: +8615380400285
Correo electrónico: sales2@liwei-chem.com
Condiciones de pago flexibles, precio competitivo, servicio de primera calidad: ¡consúltenos ahora!
| Parameter | PVA 0588 | PVA 1788 | PVA 1799 |
|---|---|---|---|
| Degree of hydrolysis (mol%) | 87.0–89.0 | 87.0–89.0 | ≥98.0 |
| Viscosity, 4% aq., 20 °C (cP) | 5.0–6.0 | 20.0–30.0 | 25.0–35.0 |
| Tensile strength, unplasticised film (MPa, ASTM D882) | 25–35 | 55–70 | 80–120 |
| Elongation at break, unplasticised (%) | 5–15 | 10–30 | 5–10 |
| Swelling ratio at 90% RH, 25 °C (wt%) | ~45 | ~35 | ~20 |
| Water dissolution temperature, non-crosslinked (°C) | ~15 | ~40 | ≥70 |
| Property | PVA 1799 (plasticised, 15% glycerol) | PDMS (Sylgard 184, 10:1) | TPU (Estane 58277) |
|---|---|---|---|
| Young’s modulus (MPa) | 380–520 | 1.2–2.5 | 12–25 |
| Elongation at break (%) | 180–260 | 120–170 | 450–650 |
| Dielectric constant (1 kHz) | 8.2 | 2.7 | 5.5 |
| Water uptake at 100% RH, 24 h (%) | 38 | <0.1 | 1.2 |
| Gauge factor (5 wt% MWCNT, 0–50% strain) | 75–110 | 8–18 | 25–45 |
| Hysteresis after 1000 cycles (%) | 12–14 | 3–5 | 18–22 |
| Biodegradation standard compliance | ASTM D6400 (industrial composting) | None | None |
| ISO 10993-5 cytotoxicity | Pass (>80% viability) | Pass post-extraction | Pass (>70% viability) |